ANSI/AWI 0641-2019 - Architectural Wood Casework
5.0 Supplemental Information
5.1 Glossary
a)?The Architectural Woodwork Institute Glossary can be found at:?Click Here
5.2 Design Professional Responsibilities
a) Glass type, thickness, and edge treatment of glass shelving
b) Door and drawer front Interface style.
c) Door and drawer front edge profile.
d) Toe kick finish.
e) Grain direction, if other than vertical.
f) Interior clearance.
g) Seismic fabrication and/or installation.
h) Flame spread rating.
i) Moisture resistance.
j) Insulation from heating and cooling sources.
k) Hardware.
l) Laboratory features, such as:
? Pipe chase allowance and/or removable s behind s.
? Removable top at countertop splash.
? Moisture resistant base.
? Chemical resistant finish or surfaces.
a)?Species of veneer.
b)?Method of slicing (plain, quarter, rift, or rotary).
c)?Matching of veneer leaves (book, slip, or random).
d)?Matching of veneer leaves within the face of a .
e)?Matching between doors, drawers, and s (non-sequenced, sequenced, or blueprint).
f)?End matching.
g)?Grain direction, if other than vertical.
5.3 Surface Categories
a) Defined as all exterior surfaces exposed to view, including:
? All surfaces visible when doors and drawers are closed, including knee spaces.
? Underside of cabinet bottoms over 1067 mm [42”] above the finished floor, including cabinet bottoms behind light valances and the bottom edge of light valances.
? Cabinet tops under 2032 mm [80”] above the finished floor, or if 2032 mm [80”] and over and visible from an upper building level or floor.
? Front edges of stretchers, ends, s, tops, and bottoms.
? Sloping tops of cabinets that are visible.
a) Defined as all interior surfaces exposed to view in open casework or behind transparent doors, including:
? Shelves, including edgebanding.
? Divisions and partitions (front edge is an exposed surface).
? Interior face of ends (sides), backs, and bottoms (including pull outs). Also included are the interior surfaces of cabinet top members 914 mm [36”] or more above the finished floor.
? Interior face of door and applied drawer fronts.
a) Defined as those interior surfaces only exposed to view when doors or drawers are opened, including:
? Tops and bottoms of shelves, including front edgebanding (front edge is an exposed surface).
? Divisions and partitions (front edge is an exposed surface).
? Interior face of ends (sides), backs, and bottoms (including a bank of drawers). Also included are the interior surfaces of cabinet top members 914 mm [36”] or more above the finished floor.
? Drawer sides, sub fronts, backs, and bottoms.
? The underside of cabinet bottoms between 610 mm [24”] and 1067 mm [42”] above the finished floor.
? Security panels or drawer stretchers.
a) Defined as those exterior or interior surfaces that are covered or not normally exposed to view, including:
? Toe spaces, unless otherwise specified.
? Sleepers, stretchers, and solid sub tops.
? The underside of cabinet bottoms less than 610 mm [24”] above the finished floor.
? The flat tops of cabinets 2032 mm [80”] or more above the finished floor, except if visible from an upper floor or building level.
? The three non-visible edges of adjustable shelves.
? The underside of knee spaces, s and drawer boxes that are less than 914 mm [36”] above the finished floor.
? The faces of cabinet ends of adjoining units that butt together.
5.4 AWI Performance Duty Level Typical Applications
Performance Duty Level | Typical Application |
---|---|
Duty Level 1 | Light Commercial |
Duty Level 2 | Commercial |
Duty Level 3 | Institutional |
Duty Level 4 | Laboratory |
5.5 References
a) ANSI/ HP-1 (latest edition)
b) ASTM D1037 (latest edition)
c) ANSI/WDMA I.S.1A (latest edition)
d) ANSI/WDMA I.S.6A (latest edition)
e) ANSI Z97.1 (latest edition)
f) ANSI/AWI 0620 – Finish Carpentry/Installation (latest edition)
g) AWI 300 – Materials (latest edition)
h) AWI Finishing Standard, current edition
i) AWI Casework Installation Guidelines
j) AWI Tested and Approved Methods and Materials for Casework Construction
k) ANSI/BHMA Standards (latest edition)
l) ANSI/BHMA A156.9 (latest edition)
m) ISO 4586-2-2018